ja_mageia

QDA 1000 Series

collage

QDA 1000 Series is a multi-channel (4, 8, 16)  Data Acquisition System. It is currently being used in various fields such as monitoring health of civil structures, acoustic and vibration sensing and many more...

Product Info

Take a look at the critical specifications of QDA 1000 series of Data Acquisition Systems.

 QDA 1008
  • 8 (multiplexed) analog inputs.                
  • Sampling frequency: 1kHz/channel.        
  • Sampling jitter: 50µSec.                        
  • ADC-resolution 16-bit.                        
qda_front

 Signal Conditioner
  • Suitable for the outputs of microphones, piezo-sensors etc.
  • Input type: balanced/differential.
  • Input range: Common Mode Voltage (±10V), Differential Voltage (±2.5V).
  • Input gain: 1 (can be changed according to requirement).
  • Input impedance: 1012Ω.
electronics

 Data Storage & Operating System Portability
  • The acquired data can be exported to ASCII file and read by Excel, Origin, Matlab etc.
  • The software restores the last configuration every time, it is launched.
  • The software works on Linux, WinXP, Windows Vista, Windows 7.
main_window6

 Trace Control:
  • Simultaneous 8-channels plotting.
  • Individual Y-axis scaling.
  • Individual Y-axis offset.
  • Individual trace activation or de-activation.          
main_window2

 Trigger Control, Time-base control
  • Three mode trigger: auto, normal and single.
  • Trigger Slope: falling and rising.
  • Any of the 8-channels can be used as trigger source.
  • Adjustable trigger level.
  • Preset Acquisition times: 20ms, 50ms, 100ms, 200ms, 500ms, 1sec, 2sec, 5sec, 10sec, 20sec, 50sec & 100sec.
main_window7

For more information and purchase-RELATED QUERRIES, please send us an enquiry here.

Specifications

Hardware
No. of channels 4, 8, 16 (Multiplexed)
ADC Resolutions 16-bit
Sampling frequency 1KHz/Channel
Sampling jitter 50µsec

Virtual Oscilloscope (QDA Software)
Trace Control Activation or de-activation facility
Trigger Control Multi-channel control
Trigger Modes Auto, normal & single
Trigger Level Adjustable
Trigger Slope Falling & rising
Preset Acquisition Times 20ms , 50ms, 100ms, 200ms, 500ms, 1sec, 2sec, 5sec, 10sec, 20sec, 50sec, 100sec
Data Export ASCII file
Readable Data By Excel, Origin, Matlab etc.

Standard Accessories
Serial Cable Two
User Manual One
Software Provided in CD

Minimum Computer Requirement
Computer Pentium IV & above
Platform Linux, MS Windows XP, Windows Vista, Windows 7
Main Memory 1GB
Hard Disk Drive 128 MB free space
Compact Disk Drive Standard
Coloured Monitor Min. 1024x768 resolution
Serial Port Two

Installation Requirements
Power Input 220Vac/50Hz (±1%)
Temperature 50ºC (Max.)
Dimensions L=25cm, W=25.5cm, H=13.7cm
Weight 3.7 kg

 

For more information and purchase-RELATED QUERRIES, please send us an enquiry here.

Images

For more information and purchase-RELATED QUERRIES, please send us an enquiry here.

Application Notes

QDA Series Brochure (pdf)

For more information and purchase-RELATED QUERRIES, please send us an enquiry here.

 
Banner

User login






Loading
We have 58 guests and 1 member online